首页
文献服务
文献资源
外文期刊
外文会议
中文期刊
专业机构
智能制造
高级检索
版权声明
使用帮助
Imaging composite material using ultrasonic arrays
     
  
  
刊名:
NDT & E International
作者:
Chuan Li
(University of Bristol, Queens Building, University Walk)
Damien Pain
(University of Bristol, Queens Building, University Walk)
Paul D. Wilcox
(University of Bristol, Queens Building, University Walk)
Bruce W. Drinkwater
(University of Bristol, Queens Building, University Walk)
刊号:
713C0009
ISSN:
0963-8695
出版年:
2013
年卷期:
2013, vol.53
页码:
8-17
总页数:
10
分类号:
TB4; TG115
关键词:
Total focusing method
;
Full matrix capture
;
Anisotropic
;
Direction-dependant velocity
参考中译:
语种:
eng
文摘:
As carbon fibre composite becomes more widely used for primary structural components in aerospace and other applications, the reliable detection of small defects in thick-sections is increasingly important. This article describes an experimental procedure for improving the detectability of such defects based on modifications to the Total Focusing Method (TFM) of processing ultrasonic array data to form an image. First the TFM is modified to include the directional dependence of ultrasonic velocity in an anisotropic composite laminate, and practical procedures for measuring the direction-dependent velocity profile are described. The performance of the TFM is then optimised in terms of the signal to noise ratio for Side-Drilled Holes (SDHs) by tuning both the frequency-domain filtering of data and the maximum aperture angle used in processing. Finally an attenuation correction is applied to the image so that the background structural noise level is uniform at all depths. The result is an image where the sensitivity (i.e. the signal to noise ratio) to a particular feature is independent of depth. Signals from 1.5 mm diameter SDHs in the final image at depths of 4, 10 and 16 mm are around 15 dB above the root-mean-square level of the surrounding structural noise. In a standard TFM image, the signals from the same SDHs are not visible above the structural noise.
相关文献:
Total Focusing Method for Volumetric Imaging in Immersion Non Destructive Evaluation
PERFORMANCE EVALUATION OF TOTAL FOCUSING METHOD ON GPP AND GPU
Efficient Imaging Techniques Using Sub-aperture Matrix Capture and Two-dimensional Sparse Array
The efficiency optimization of full matrix capture imaging detection based on increasing the effective aperture
Simulation study to improve the detection of planar defects located under shrinkage cavities
Effects of array transducer inconsistencies on total focusing method imaging performance
Imaging composite material using ultrasonic arrays
ВОССТАНОВЛЕНИЕ ИЗОБРАЖЕНИЯ ОТРАЖАТЕЛЕЙ ПО УЛЬТРАЗВУКОВЫМ ЭХОСИГНАЛАМ МЕТОДОМ МАКСИМАЛЬНОЙ ЭНТРОПИИ
ВОССТАНОВЛЕНИЕ ИЗОБРАЖЕНИЯ ОТРАЖАТЕЛЕЙ КОРРЕЛЯЦИОННЫМ МЕТОДОМ ПРИ ПРОИЗВОЛЬНОМ КОЛИЧЕСТВЕ ОТРАЖЕНИЙ УЛЬТРАЗВУКОВОГО ИМПУЛЬСА ОТ ГРАНИЦ ОБЪЕКТА КОНТРОЛЯ, СОСТОЯЩЕГО ИЗ ОБЛАСТЕЙ С РАЗНЫМИ АКУСТИЧЕСКИМИ СВОЙСТВАМИ
ВОССТАНОВЛЕНИЕ ИЗОБРАЖЕНИЯ ОТРАЖАТЕЛЕЙ МЕТОДОМ C-SAFT С УЧЕТОМ АНИЗОТРОПИИ МАТЕРИАЛА ОБЪЕКТА КОНТРОЛЯ
©2016机械工业出版社(机械工业信息研究院) 京ICP备05055788号-35